9,2

Scientific Research

The secret for best clinical practice

Achterste Kruisband: Kniespecialist RPA Janssen is topspecialist voor achterste kruisbandletsels van de knie. Topsport: Kniespecialist RPA Janssen is topspecialist voor alle knieblessures.
Read more →

Keynote lecture KNGF: Up to date treatment ACL injury

Nicky van Melick PT PhD and Rob...

Read more →

EORS 2019

RPA Janssen MD PhD Prof will visit the EORS 2019 Congress. He is member of the scientific committee and chair of 2 symposia...

Read more →

Faculty NVA Advanced Knee Course

RPA Janssen MD PhD Assoc Prof is faculty at the...

Follow me!

Remain up to date with all the latest knee facts via Facebook, Twitter and other social networks


Measurement properties of the OARSI core set of performance-based measures for hip osteoarthritis. A prospective cohort study on reliability, construct validity and responsiveness in 90 hip osteoarthritis patients.

Measurement properties of the OARSI core set of performance-based measures for hip osteoarthritis. A prospective cohort study on reliability, construct validity and responsiveness in 90 hip osteoarthritis patients.

Tolk JJ, Janssen RPA, Prinsen C, van der Steen MC, Sita Bierma-Zeinstra S, Reijman M
Acta Orthop. 2019 Feb;90(1):15-20

Abstract

Background and purpose - Improvement of physical function is one of the main treatment goals in severe hip osteoarthritis (OA) patients. The Osteoarthritis Research Society International (OARSI) has identified a core set of performance-based tests to assess the construct physical function: 30-s chair stand test (30-s CST), 4x10-meter fast-paced walk test (40 m FPWT), and a stair-climb test. Despite this recommendation, available evidence on the measurement properties is limited. We evaluated the reliability, validity, and responsiveness of these performance-based measures in patients with hip OA scheduled for total hip arthroplasty (THA). Patients and methods - Baseline and 12-month follow-up measurements were prospectively obtained in 90 end-stage hip OA patients who underwent THA. As there is no gold standard for comparison, the hypothesis testing method was used for construct validity and responsiveness analysis. A test can be assumed valid if ≥75% of predefined hypotheses are confirmed. A subgroup (n = 30) underwent test-retest measurements for reliability analysis. The Oxford Hip Score, Hip injury and Osteoarthritis Outcome Score-Physical Function Short Form, pain during activity score, and muscle strength were used as comparator instruments. Results - Test-retest reliability was appropriate; intraclass correlation coefficient values exceeded 0.70 for all 3 tests. None of the performance-based measures reached 75% hypothesis confirmation for the construct validity or responsiveness analysis. Interpretation - The performance-based tests have good reliability in the assessment of physical function. Construct validity and responsiveness, using patient-reported measures and muscle strength as comparator instruments, could not be confirmed. Therefore, our findings do not justify their use for clinical practice.


← Back to publications

 

RPA Janssen, MD PhD 
Orthopaedic Surgeon
Orthopaedic Associates Eindhoven Greater Area
Orthopedic Center Máxima
Máxima Medical Center (MMC)

Visiting adress MMC Eindhoven:
Ds. Th. Fliednerstraat 1
Ingang Zuid
5631 BM  Eindhoven
The Netherlands 
(outpatient clinic and surgery)

Visiting adress MMC Veldhoven:
De Run 4600
5504 DB  Veldhoven
The Netherlands
(Outpatient clinic)

Mail adress:
Postbus 90052
5600 PD  Eindhoven
The Netherlands

Tel. 0031 (0)40 88 88 600
(Call center Orthopedie)

Fax: 0031 (0)40 88 85 938
www.rpajanssen.com 

Links:
Orthopaedic Associates Eindhoven Greater Area
Máxima Medical Center
Orthopaedic Center Máxima
 

RPA Janssen YouTube
RPA Janssen Twitter
RPA Janssen Facebook
RPA Janssen LinkedIn
RPA Janssen weblog




s2